Product Description
Specification
| Operation Mode | Automatic |
| Types | Conventional |
| Rotation Time | 8 Seconds |
| Application | Hospital, Diagnostic Centre |
| Brand | GE Healthcare |
| Bore Size | 70 cm |
| Tube MHU | 3.5 |
| Generator | 42 kW |
| Gantry Tilt | +/-30 Degrees |
| Detectors | Solid State (HiLight) |
| Power | 36 kW |
| Focal Spot | 0.9mm x 0.62mm and 1.2mm x 1.2mm |
High-Speed Imaging for Enhanced DiagnosticsEngineered for speed and accuracy, the Hi Speed CT delivers scan times under 1 second per slice, minimizing patient discomfort while achieving high-resolution images. With slice thickness adjustable from 0.5 mm to 5 mm, clinicians can tailor the scans for varied diagnostic needs, ensuring both precision and versatility.
Safety and Comfort PrioritizedSafety is paramount with integrated radiation shielding, emergency stop functions, and patient monitoring systems. The system operates below 65 dB, reducing noise in clinical settings, while the spacious 700 mm gantry and sturdy patient table accommodate a wide range of patients with a maximum load of 205 kg.
Advanced Software & Connectivity FeaturesThe scanners advanced image processing and 3D reconstruction software ensures diagnostic clarity, while connectivity with PACS and DICOM streamlines data sharing and archiving. Real-time reconstruction and a user-friendly console display enable efficient workflow for both clinicians and technicians.
FAQs of GE Hi Speed CT Scanner:
Q: How does the GE Hi Speed CT Scanner ensure high accuracy in diagnostic imaging?
A: The scanner uses high precision scanning technology with a slice thickness ranging from 0.5 mm to 5 mm, ensuring detailed imaging down to approximately 0.1 mm. Advanced image processing and 3D reconstruction further enhance diagnostic accuracy for whole-body and organ scans.
Q: What safety features are incorporated in the Hi Speed CT Scanner?
A: This CT scanner integrates comprehensive safety measures such as radiation shielding, an emergency stop button, robust patient monitoring, and operates at noise levels below 65 dB. These features collectively protect both patients and medical staff during operation.
Q: When is real-time image reconstruction utilized during scanning?
A: Real-time image reconstruction occurs throughout each scan, allowing clinicians to access high-quality images instantly. This feature speeds up diagnostic workflow and enables timely medical decision-making in acute or routine settings.
Q: Where can the GE Hi Speed CT Scanner be installed?
A: With its compact footprint and single-phase power requirements, the scanner is suitable for installation in hospitals, clinics, and medical centers. Its design allows for easy integration even in facilities with limited space.
Q: What is the process for patient imaging with this CT scanner?
A: Patients are safely positioned on the table (supporting up to 205 kg), and scanning is performed using automated controls. Slices are acquired in under 1 second each, and images are reconstructed in real-time, with data immediately available for review or transfer via PACS/DICOM.
Q: How does the scanner benefit both patients and clinicians?
A: Patients experience reduced scan times and minimized radiation dose, while clinicians benefit from rapid, high-resolution imaging and advanced diagnostic tools. Seamless connectivity and automation elevate workflow efficiency and diagnostic confidence.
Q: Is technical service and remote accessibility supported for this equipment?
A: Yes, the GE Hi Speed CT Scanner is supported by both onsite and remote technical service options, along with remote accessibility features for monitoring and troubleshooting, which ensures consistent operation and minimal downtime.